Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
This test is not available for New York patient testing.
RBC Zinc
Specimen requirements | |
|---|---|
| Patient preparation | None Specified |
| Preferred specimen(s) | 0.5 mL red blood cells collected in an EDTA trace metal-free (royal blue-top) tube |
| Alternative specimen(s) | Red blood cells collected in: EDTA (lavender-top), sodium heparin trace metal-free (royal blue-top), sodium heparin (green-top), sodium heparin lead-free (tan-top), or lithium (green-top) tube |
| Minimum volume | 0.3 mL |
| Collection instructions | Red blood cells trace metal: Use the royal blue-top trace metal evacuated tube with EDTA or sodium heparin, for RBC trace metal testing. Packed Cells: Centrifuge to separate plasma from RBC's and discard plasma. Transfer RBC's to a plastic transfer vial from a Quest Diagnostics (trace element and metal-free) collection kit or transfer to a plastic screw-cap vial. |
| Transport container | See Collection Instructions |
| Transport temperature | Room temperature |
| Specimen stability | Room temperature: 7 days Refrigerated: 10 days Frozen: Unacceptable |
| Reject criteria | Moderate hemolysis • Clotted |
The Result and LOINC® information listed below should not be used for electronic interface maintenance with Quest Diagnostics. Please contact the Quest Diagnostics Connectivity Help Desk for more information at 800-697-9302.
NOTE: The codes listed in the table are not orderable Test Codes
Result code | Result name | LOINC code | Component name |
|---|---|---|---|
| 85992436 | ZINC, RBC | 5761-2 | Zinc |
| med fusion |
| 2501 South State Hwy 121, Suite 1100 |
| Lewisville, TX 75067-8188 |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.