The information below details the components of this test. For overall setup schedule, see Performing lab & setup schedule.
Test code | Test name | Orderable separately | Setup schedule |
|---|---|---|---|
| 964 | Measles Antibody (IgG), Immune Status | Yes | Set up: Mon, Wed, Fri; Report available: 4 days |
| 8624 | MUMPS VIRUS AB (IGG),IMMUNE STATUS | Yes | Not provided |
| 802 | Rubella Antibody (IgG), Immune Status | Yes | Set up: Mon-Fri; Report available: 4 days |
Measles Antibody (IgG), Immune Status
Mumps Virus Antibody (IgG), Immune Status
Rubella Antibody (IgG), Immune Status
Immunoassay (IA)
Mumps Virus Antibody,IgG,Serum,Anti-Rubella Ab IgG,Measles,German,Anti-German Measles Ab IgG,Rubella Antibody Index,German Measles Antibody,Rubella Titer,Rubella IgG,Rubella Screen
Specimen requirements | |
|---|---|
| Patient preparation | None Specified |
| Preferred specimen(s) | 2 mL serum |
| Minimum volume | 1 mL |
| Transport container | Transport tube |
| Transport temperature | Room temperature |
| Specimen stability | Room temperature: 4 days Refrigerated: 7 days Frozen: 30 days |
| Reject criteria | Gross hemolysis • Grossly lipemic • Icteric |
The Result and LOINC® information listed below should not be used for electronic interface maintenance with Quest Diagnostics. Please contact the Quest Diagnostics Connectivity Help Desk for more information at 800-697-9302.
NOTE: The codes listed in the table are not orderable Test Codes
Result code | Result name | LOINC code | Component name |
|---|---|---|---|
| 70012000 | RUBELLA AB (IGG), IMMUNE STATUS | 5334-8 | Rubella virus Ab.IgG |
| 70021500 | MEASLES AB (IGG), IMMUNE STATUS | 5244-9 | Measles virus Ab.IgG |
| 70022000 | MUMPS VIRUS AB (IGG), IMMUNE STATUS | 25418-5 | Mumps virus Ab.IgG |
| Quest Diagnostics - Southwest Region |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.
*The CPT codes provided are based on AMA guidance and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.
This material contains content from LOINC® (http://loinc.org). The LOINC Table, LOINC Table Core are copyright © 1995-2019, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license.
The tests listed by specialty and category are a select group of tests offered. For a complete list of Quest Diagnostics tests, please adjust the filter options chosen, or refer to our Directory of Services.