Carbamazepine-10,11-Epoxide, Serum/Plasma
Test Code
Clinical Significance
Carbamazepine-10,11-Epoxide, Serum/Plasma - Carbamazepine and its metabolite (10,11-Carbamazepine epoxide) are widely used for control of generalized tonic-clonic, partial-onset, complex and mixed seizure disorders. The metabolism of carbamazepine in epileptic patients has several different pathways that can be altered when the patient is co-medicated with other anticonvulsants and, therefore, its therapeutic level should be monitored along with its metabolite in their free and protein bound states.
Test Resources
Test Details
Methodology
Reference Range(s)
Preferred Specimen(s)
2 mL serum collected in a red-top tube (no gel)
Alternative Specimen(s)
Plasma collected in: EDTA (lavender-top) tube
Minimum Volume
1 mL
Collection Instructions
Centrifuge and immediately separate serum or plasma specimens from the cells into clean, plastic transport tube.
Transport Container
Transport tube
Transport Temperature
Room temperature
Specimen Stability
- Room temperature: 14 days
- Refrigerated: 14 days
- Frozen: 10 months
Reject Criteria
Serum separator tube (SST)
Setup Schedule
Refrigerated: 14 days
Frozen: 10 months