Real-Time Polymerase Chain Reaction
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Adenovirus DNA Qual PCR
Specimen requirements | |
|---|---|
| Patient preparation | None Specified |
| Preferred specimen(s) | Throat or nasopharyngeal swab submitted in 1 mL M4 media, VCM (green-cap), or equivalent (UTM) tube |
| Alternative specimen(s) | 1 mL serum • 1 mL whole blood or plasma collected in EDTA (lavender-top) tube • 1 mL CSF, sputum, or urine collected in a sterile leak-proof container • 1 mL bronchial, nasopharyngeal, or tracheal lavage/wash collected in a sterile plastic leak-proof container • 3 cubic mm tissue collected in a sterile plastic leak-proof container • Eye swab (conjunctival) in an M4, VCM (green-cap) container or equivalent |
| Minimum volume | 3 cubic mm tissue • 0.6 mL all other specimen types |
| Transport container | M4, VCM (green-cap), or equivalent (UTM) tube |
| Transport temperature | Tissue and sputum: Frozen All other specimens: Refrigerated (cold pack) |
| Specimen stability | Whole blood and urine Room temperature: 48 hours Refrigerated: 7 days Frozen: Unacceptable Sputum Room temperature: Unacceptable Refrigerated: Unacceptable Frozen: 30 days All other specimens Room temperature: 48 hours Refrigerated: 7 days Frozen: 30 days |
| Reject criteria | Sodium heparin (green-top) tube • Lithium heparin (green-top) tube • Calcium alginate swabs |
The Result and LOINC® information listed below should not be used for electronic interface maintenance with Quest Diagnostics. Please contact the Quest Diagnostics Connectivity Help Desk for more information at 800-697-9302.
NOTE: The codes listed in the table are not orderable Test Codes
Result code | Result name | LOINC code | Component name |
|---|---|---|---|
| 86002433 | ADENOVIRUS DNA, QL REAL TIME PCR | 39528-5 | Adenovirus DNA |
| 86002938 | SOURCE | 31208-2 | Specimen |
| Quest Diagnostics Nichols Institute-Chantilly VA |
| 14225 Newbrook Drive |
| Chantilly , VA 20151-2228 |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.
*The CPT codes provided are based on AMA guidance and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.
This material contains content from LOINC® (http://loinc.org). The LOINC Table, LOINC Table Core are copyright © 1995-2019, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license.