Microscopic Examination
Partial Acid Fast Stain
Specimen requirements | |
|---|---|
| Patient preparation | Expectorated sputum: Instruct the patient to rinse his/her mouth and gargle with water prior to collection. Tell the patient not to expectorate saliva or postnasal discharge into the container. 3 separate samples should be collected over an 8-24 hour interval of time. Include at least one first morning specimen. For follow-up patients on therapy, collect at intervals beginning 3 weeks after initiation of therapy. Induced sputum: Use a wet toothbrush and brush the buccal mucosa, tongue, and gums of the patient prior to collection. Rinse the patient's mouth thoroughly with water. Invasive procedures such as transtracheal aspirate, bronchial biopsy and fine needle aspirate yield the highest percentage of positive results. Aerosol-induced sputum: Using an ultrasonic nebulizer, have patient inhale approximately 20-30 mL of sterile hypertonic saline. Avoid sputum contamination with nebulizer reservoir water. Bronchial washings and bronchoalveolar lavage fluids: Generally obtained before brushings or biopsy to avoid excess blood in the specimen. Aspirate or lavage specimens that are collected in traps should be transferred to a sterile, screw cap conical tube to avoid leakage during transport. Tissue and biopsy material: Obtain a sample as large as possible in a small amount of sterile, non-bacteriostatic saline. Urine: Appropriate cleaning of the genitalia must precede collection. Collect entire first morning specimen (> 40 mL) on 3 consecutive days. Organisms may accumulate in the bladder overnight, so first morning void provides the best yield. |
| Preferred specimen(s) | 5-10 mL respiratory specimens including expectorated sputum, aerosol-induced sputum, bronchial washing, bronchial brushing, transtracheal aspirate, bronchoalveolar lavage fluid collected in a sterile leak-proof container As much as possible of biopsy, aspirate or granules from lung, sinus tract, subcutaneous tissue, central nervous system collected in a sterile leak-proof container or other systemic sites collected in a culture swab in Amies liquid transport swab, Amies gel transport swab, Amies liquid elution swab (ESwab) or equivalent 5 mL body fluid collected in a sterile leak-proof container 2 mL CSF collected in a sterile leak-proof container 40 mL entire first morning voided urine collected in a sterile leak-proof container |
| Minimum volume | 2 mL respiratory specimen • 2 mL body fluid • 1 mL CSF • 20 mL urine |
| Collection instructions | Culture recommended in addition to stain |
| Transport container | Sterile leak-proof container or Culture swab in Amies liquid transport swab, Amies gel transport swab, Amies liquid elution swab (ESwab) or equivalent |
| Transport temperature | Refrigerated (cold packs) |
| Specimen stability | Room temperature: Unacceptable Refrigerated: 5 days Frozen: Unacceptable |
| Reject criteria | 24 hour pooled urine • 24 hour pooled sputum • Dry swabs • Specimens received in alcohol, formalin, EDTA, lithium heparin or conventional blood culture bottles • Swabs or raw unpreserved specimen >5 days old • Throat/oral/sputum from non-cystic-fibrosis patients • Stool specimens • Urine specimens in preservative tubes • Red-top (silica-containing) plastic tubes and tubes with additives or clot activator • Prepared slides from client • Specimens received in expired transports |
The Result and LOINC® information listed below should not be used for electronic interface maintenance with Quest Diagnostics. Please contact the Quest Diagnostics Connectivity Help Desk for more information at 800-697-9302.
NOTE: The codes listed in the table are not orderable Test Codes
Result code | Result name | LOINC code | Component name |
|---|---|---|---|
| 75400730 | RESULT: | 655-1 | Observation |
| med fusion |
| 2501 S. State Hwy 121, Ste 1100, Microbiology Dept |
| Lewisville, TX 75067-8188 |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.
*The CPT codes provided are based on AMA guidance and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.
This material contains content from LOINC® (http://loinc.org). The LOINC Table, LOINC Table Core are copyright © 1995-2019, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license.
The tests listed by specialty and category are a select group of tests offered. For a complete list of Quest Diagnostics tests, please adjust the filter options chosen, or refer to our Directory of Services.