ALK Variant,
AKT1 Variant
BRAF Variant
EGFR Variant
ERBB2 (HER2) Variant
KRAS Variant
MAP2K1 (MEK1) Variant
NRAS Variant
PIK3CA (PI3K) Variant
PTEN Variant
ALK Rearrangement
RET Rearrangement
ROS1 Rearrangement
MET Amplification
Next Generation Sequencing • Fluorescence in situ Hybridization (FISH)
This test was developed and its performance characteristics determined by MedFusion. It has not been cleared or approved by the U.S. Food and Drug Administration (FDA). The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes. It should not be regarded as investigational for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high complexity clinical laboratory testing.
Lung Cancer,FISH,c-MET,Next Generation Sequencing,NSCLC,NGS,Non-Small Cell Lung Cancer (NSCLC),ALK,RET,ROS1
Specimen requirements | |
|---|---|
| Patient preparation | None Specified |
| Preferred specimen(s) | Paraffin-embedded tissue accompanied by a circled H&E slide indicating the area to be examined collected in a sterile biohazard plastic bag or 19 formalin-fixed paraffin-embedded tissue slides and H&E slide collected in a slide holder |
| Alternative specimen(s) | Paraffin-embedded tissue block or slides |
| Collection instructions | Do not freeze. Do not reject. Please submit pathology report for FFPE and slides. Specimen to be tested should contain a minimum of 10% tumor nuclei. Decalcified specimens are not acceptable. All specimens must be accompanied with pathology report. All FFPE specimens will be examined by a pathologist for confirmation and adequacy. Macrodissection if warranted is performed in the lab. |
| Transport container | Paraffin-embedded tissue with H&E slide in biohazard plastic bag |
| Transport temperature | Room temperature |
| Specimen stability | Room temperature: Preferred Refrigerated: Acceptable Frozen: Unacceptable |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.
*The CPT codes provided are based on AMA guidance and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.
This material contains content from LOINC® (http://loinc.org). The LOINC Table, LOINC Table Core are copyright © 1995-2019, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license.
The tests listed by specialty and category are a select group of tests offered. For a complete list of Quest Diagnostics tests, please adjust the filter options chosen, or refer to our Directory of Services.