10240 - Micronutrient, Arsenic, Blood
10242 - Micronutrient, Cadmium, Blood
10244 - Micronutrient, Cobalt, Blood
10251 - Micronutrient, Lead, Blood
10254 - Micronutrient, Mercury, Blood
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Specimen requirements | |
|---|---|
| Patient preparation | None Specified |
| Preferred specimen(s) | 4 mL whole blood collected in an EDTA (royal blue-top) tube |
| Alternative specimen(s) | Whole blood collected in: Sodium heparin (royal blue-top) tube Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that re-submission with a trace element tube/container is recommended. Note: Lead testing will not be performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container. |
| Minimum volume | 2 mL |
| Collection instructions | Patients should be 18 years of age or greater. Do not aliquot specimens. Avoid worksite collection. Phlebotomist should wear powderless gloves. Collection material such as alcohol swab should be lead-free. Once washed, fingers must not come in contact with any surface. |
| Transport container | EDTA (royal blue-top) tube |
| Transport temperature | Refrigerated (cold packs) |
| Specimen stability | Room temperature: 10 days Refrigerated: 14 days Frozen: 30 days |
| Reject criteria | Clotted • EDTA (lavender-top) tube |
Reference ranges are provided as general guidance only. To interpret test results use the reference range in the laboratory report.
*The CPT codes provided are based on AMA guidance and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.
This material contains content from LOINC® (http://loinc.org). The LOINC Table, LOINC Table Core are copyright © 1995-2019, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license.
The tests listed by specialty and category are a select group of tests offered. For a complete list of Quest Diagnostics tests, please adjust the filter options chosen, or refer to our Directory of Services.